Sloan Optima EAF-200 Parts Breakdown and Troubleshooting
View complete faucet models:
• EAF-200 0.5 GPM Single Supply (Plug-In Adapter)
• EAF-200 0.5 GPM Single Supply with Mixer (Plug-In Transformer)
• EAF-200 0.5 GPM with Mixer (Battery Powered)
- 1A. #87289 - EAF-18-A - Faucet Sensor Assembly with i.q. cliq
1B. - EAF-19-A - Faucet Sensor Assembly without i.q. cliq - 2. #49787 - EAF-27 - Cap
- 3A. 0335012 - EAF-15 - Vandal Resistant Aerator Spray Head 0.5 GPM (Pre-03/2011)
3B. #80153 - EAF-10 - Aerator Spray Head 2.2 GPM
3C. #80774 - EAF-13 - Laminar Flow Spray Head 2.2 GPM
3D. 0335029 - EAF-51 - Multi-Laminar Spray Head 0.35 GPM - 4. #80154 - EAF-1 - Faucet Mounting Kit
- 5. #80759 - EAF-9 - Filter Strainer
- 6A. #49786 - EAF-1004 - Mixer Handle Assembly & Cartridge
6B. #80777 - EAF-1005 - Handle Repair Kit - 7. #80778 - EAF-1007 - Handle Cap
- 8. #84115 - EAF-1008 - 13" Flexible Supply Hose
*Please note that any items that do not have links must be called in to order.
- 9. #81828 - EAF-44 - Power Splitter
- 10. #84122 - EAF-24-A - Extension Cable (11-13/16")
#84123 - EAF-25-A - Extension Cable (47-1/4")
#84124 - EAF-17-A - Extension Cable (126") - 11. #58426 - EAF-2 - Solenoid
- 12. #54676 - ETF-312-A - 4" Trim Plate
- 13. #52154 - ETF-510-A - 8" Trim Plate
- 14. #84118 - EAF-11 - Plug-in Adapter
- 15. #80779 - EAF-35-A - Faucet Extension Kit
- 16. #84767 - EAF-37 - 6 VDC Box Mount Voltage Adapter
-
Not Shown -
EAF-28 - Capacitor Box (Model EAF-200) - Obsolete
EAF-40-A - 2-1/4" Faucet Extension Kit
- Complete Units: #83147, #83148, #84729
Troubleshooting Q&A
Below is a Troubleshooting Q&A Guide for the EAF-200 Electronic Faucets from Sloan. This guide highlights the most commonly occurring problems and how to go about fixing them. As always you can call us for assistance or if you need to replace a part and/or unit.
1
PROBLEM:
Faucet DOES NOT function
CAUSE:
A) "Permanent Off" activated
SOLUTION:
A) Press button on faucet throat one time
2
PROBLEM:
Faucet delivers water in an uncontrolled manner
CAUSE:
A) Faucet is not working properly
SOLUTION:
A) This can happen for a variety of reasons. Knowing your particular circumstances will help us figure out if your dysfunctional faucet can be fixed, or if it needs to be replaced entirely. Please contact Equiparts at 800-442-6622 or view replacement EAF-200 complete faucets: #83147, #83148, #84729.
3
PROBLEM:
Faucet DOES NOT deliver any water when sensor is activated
INDICATOR: Solenoid valve products an audible "CLICK"
CAUSE:
A) Water supply stop(s) closed
B) Water supply stop strainer(s) clogged
SOLUTION:
A) Open water supply stop(s)
B) Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s) if required.
INDICATOR: Solenoid valve DOES NOT produce an audible "CLICK"
CAUSE:
A) Power failure (EAF-200 models)
SOLUTION:
A) Check power supply
4
PROBLEM:
Faucet delivers only a slow flow or dribble when sensor is activated
CAUSE:
A) Water supply stop(s) are partially closed
B) Water supply stop strainer(s) clogged
C) Aerator is clogged
D) Faucet is not working properly
SOLUTIONS:
A) Completely open water supply stop(s).
B) Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s) if required.
C) Remove, clean, and reinstall aerator. Replace aerator is required.
D) This can happen for a variety of reasons. Knowing your particular circumstances will help us figure out if your dysfunctional faucet can be fixed, or if it needs to be replaced entirely. Please contact Equiparts at 800-442-6622 or view replacement EAF-200 complete faucets: #83147, #83148, #84729.
5
PROBLEM:
Faucet DOES NOT stop delivering water or continues to drip after user is no longer detected
CAUSE:
A) Faucet is not working properly
SOLUTION:
A) This can happen for a variety of reasons. Knowing your particular circumstances will help us figure out if your dysfunctional faucet can be fixed, or if it needs to be replaced entirely. Please contact Equiparts at 800-442-6622 or view replacement EAF-200 complete faucets: #83147, #83148, #84729.
6
PROBLEM:
The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines
CAUSE:
A) Supply stops are not adjusted properly
B) For models with integral mixing valve – Mixing valve is set improperly for the water temperature desired.
SOLUTION:
A) Adjust supply stops
B) Rotate mixing valve handle clockwise to decrease water temperature or counterclockwise to increase water temperature.
Care and Cleaning Instructions
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean faucet that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating.