Sloan Valve Repair Parts, Fixtures, and Tools for Sale

Sloan Electronic Faucet Parts SF-2100, SF-2150, SF-2200, and SF-2250 P – store.sloanrepair.com

My Cart

Close

Find Sloan flushometers,  faucets, china fixtures, plumbing parts and accessories. Minimum Order $50.

Sloan Electronic Faucet Parts SF-2100, SF-2150, SF-2200, and SF-2250 Parts Breakdown and Troubleshooting Guide

Below is the parts breakdown for the Sloan SF-2100, SF-2150, SF-2200, and SF-2250 electronic faucets. Scroll down and click on the part number of the item(s) you need to repair your SF-2100, SF-2150, SF-2200, or SF-2250 faucet. (Please note: If an item does not have a link, we still carry it, but the item is not currently listed on our website. If you wish to order this item, give us a call.) Scroll past the parts diagram and you will see the troubleshooting Q&A, which highlights the most commonly occurring issues and the solutions to fix them.
SF-2100 / 2150 / 2200 / 2250 Breakdown PDF


Troubleshooting Q&A

Below is a Troubleshooting Q&A Guide for the SF-2100, SF-2150, SF-2200, SF-2250 Electronic Faucets from Sloan. The guide highlights the most commonly occurring problems and how to go about fixing them. As always you can call us for assistance or if you need to replace a part and/or unit.


1

PROBLEM:
Delivery of water is uncontrollable

SOLUTION:
A) Faucet is not working properly. Please contact Equiparts at 800-442-6622


2

PROBLEM:
Faucet does not deliver any water when Sensor is activated

INDICATOR:
Solenoid valve produces audible "CLICK."

SOLUTION:
A) Water supply stop(s) closed. Open supply stop(s) completely.

B) Water strainer in control module is clogged. Close supply stops and remove water inlet line at control module. Remove clean and reinstall strainer and water inlet line. Replace strainer if required.

INDICATOR:
Solenoid valve DOESN'T produce audible "CLICK"

SOLUTION:
A) Batteries low (battery powered models). Replace batteries.

B) Power failure (transformer powered models). Check power supply.


3

PROBLEM:
Faucet delivers only a slow flow or dribble when sensor is activated

SOLUTION:
A) Water supply stop(s) may be partially closed. Open stop(s).

B) Water strainer in control module is clogged. Close supply stops and remove water inlet line at control module. Remove, clean and reinstall strainer and water inlet line. Replace strainer if required.

C) Aerator is clogged. Remove, clean, and reinstall aerator. Replace aerator if required.

D) Faucet is not working properly. Please Contact Equiparts at 800-442-6622


4

PROBLEM:
Faucet doesn't stop delivering water or continues to drip after user is no longer being detected

SOLUTION:
A) Solenoid Valve is not working properly. Please Contact Equiparts at 800-442-6622


5

PROBLEM:
The water temperature is too hot / cold on
a faucet connected to hot / cold supply lines

SOLUTION:
A) Supply Stops are not adjusted properly. Adjust Supply Stops.

Care and Cleaning of Chrome and Special Finishes:
DO NOT use abrasive or chemical cleaners to clean flushometers as they may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, the flushometer should be protected from any splattering of cleaner. Acids and cleaning fluids can discolor or remove the chrome plating.


SF-2100 / 2150 / 2200 / 2250 Troubleshooting Guide PDF

View the Sloan SF-2100 / 2150 / 2200 / 2250 repair parts or our selection of Sloan electronic faucets.